Specifications

Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4068 013D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M2.7 x4
4068 01FF Other bus processor runtime
diagnostics detected memory failure
on riser card 2 that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
4068 0200 Other bus processor runtime
diagnostics detected memory riser
card fault
Memory DIMM Location: P1-M1
4068 0201 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.15
4068 0202 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.1
4068 0203 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.16
4068 0204 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.2
4068 020D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.1 x4
4068 020E Other bus processor runtime
diagnostics detected memory pair A
fault
Memory Pair A, Location: P1-M1.1 x2
4068 0211 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.13
4068 0212 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.3
4068 0213 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.14
4068 0214 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.4
4068 021D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.3 x4
4068 0221 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M1.11
Chapter 5. Error Code to FRU Index
145