Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4068 00A6 Other bus processor runtime
diagnostics detected no usable
memory
1. Ensure that memory is properly
installed
2. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See ″Memory
Configuration/Deconfiguration
Menu″ on page 260 for more
information.
3. Go to “MAP 1540: Minimum
Configuration” on page 52
4. If the problem is not fixed, call
service support.
4068 00A7 Other bus processor diagnostics
detected hardware problem
Go to “MAP 1540: Minimum
Configuration” on page 52.
4068 00B0 Other bus processor runtime
diagnostics detected bus controller
lock-unlock failure
System board, Location: P1
4068 00B1 Other bus processor runtime
diagnostics detected bus controller
failure
System board, Location: P1
4068 00B7 Other bus processor runtime
diagnostics detected insufficient
hardware resources to continue IPL
This error code appears after the
initial testing by the service processor
firmware on the processors and
memory completed successfully, but
a problem occurred when the
firmware tried to communicate
outside the processor and memory
complex. Suspect a problem with the
backplane, location: P1.
4068 0100 Other bus processor runtime
diagnostics detected memory riser
card fault
Memory riser card Location: P1-M2
4068 0101 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M2.15
4068 0102 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M2.1
4068 0103 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M2.16
4068 0104 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-M2.2
Chapter 5. Error Code to FRU Index