Specifications
Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4067 00A1 6xx bus processor runtime
diagnostics detected system firmware
fault
1. Check for AIX updates
2. Check for system firmware
updates
4067 00A2 6xx bus processor runtime
diagnostics detected service
processor firmware (PRD) fault
Update system firmware
4067 00A3 6xx bus processor runtime
diagnostics detected memory
plugging fault
Go to “MAP 1540: Minimum
Configuration” on page 52.
4067 00A4 6xx bus processor runtime
diagnostics detected application
caused fault
Application software
4067 00A5 6xx bus processor runtime
diagnostics detected invalid system
configuration
Verify that system components are
supported and properly installed
4067 00A6 6xx bus processor runtime
diagnostics detected no usable
memory
1. Ensure that memory is properly
installed
2. If more than one DIMM is called
out, go to the service processor
Memory
Configuration/Deconfiguration
Menu to verify memory DIMMs
state. See ″Memory
Configuration/Deconfiguration
Menu″ on page 260 for more
information.
3. Go to “MAP 1540: Minimum
Configuration” on page 52
4. If the problem is not fixed, call
service support.
4067 00A7 6xx bus processor runtime
diagnostics detected hardware
problem
Go to “MAP 1540: Minimum
Configuration” on page 52.
4067 00B0 6xx bus processor runtime
diagnostics detected bus controller
lock-unlock failure
System board, Location: P1
4067 00B1 6xx bus processor runtime
diagnostics detected bus controller
failure
System board, Location: P1
4067 00B7 6xx bus processor runtime
diagnostics detected insufficient
hardware resources to continue IPL
This error code appears after the
initial testing by the service processor
firmware on the processors and
memory completed successfully, but
a problem occurred when the
firmware tried to communicate
outside the processor and memory
complex. Suspect a problem with the
backplane, location: P1.
Chapter 5. Error Code to FRU Index
137