Specifications

Service Processor Error Codes
Attention: Follow the procedure defined in the “Checkpoint and Error Code Index” on
page 100. If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 52 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to MAP
410: Repair Checkout in
Diagnostic Information for Multiple Bus Systems
.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 7. Service Processor Error Codes
Error Code Description Action/ Possible Failing FRU
4066 0001 Scan interface basic assurance tests
detected system board fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
4066 0003 Scan interface basic assurance tests
detected processor fault
All processors, Location: P1-C1
4066 0009 Scan interface basic assurance tests
detected memory fault
Go to “MAP 1540: Minimum
Configuration” on page 52.
4066 00A0 Scan interface basic assurance tests
detected service processor firmware
fault
Update system firmware
4066 00A1 Scan interface basic assurance tests
detected system firmware fault
1. Check for AIX updates
2. Check for system firmware
updates
4066 00A2 Scan interface basic assurance tests
detected service processor firmware
(PRD) fault
Update system firmware
4066 00A3 Scan interface basic assurance tests
detected memory plugging fault
Go to “MAP 1540: Minimum
Configuration” on page 52.
4066 00A4 Scan interface basic assurance tests
detected application caused fault
Application software
4066 00A5 Scan interface basic assurance tests
detected invalid system configuration
Verify that system components are
supported and properly installed
132 Service Guide