Specifications

Table 6. Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
2602 0007 Failed to allocate bus resources to
PCI adapter
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter. See “Replacing
the Network Adapter” on page 99
for adapter information related to
this error.
5. Check for system firmware
updates. Apply if update
available.
6. Replace system board. (See note
3 on page 37.) Location: P1
2680 0A0y MX-PCI bridge BIST failure The problem is associated with
bridge y.
Replace the system board. (See note
3 on page 37.)
Location: P1
2680 0Cxx Machine check occurred 1. Replace the part identified by the
location code associated with this
error code.
2. If the location code associated
with this error code identifies an
adapter, replace it. See
“Replacing the Network Adapter”
on page 99 for adapter
information related to this error. If
replacing the adapter does not
correct the problem, replace the
system board. (See note 3 on
page 37.) Location: P1
See “Determining Location Code” on
page 99 for location code information
related to this error.
2803 0xxx Real time clock (RTC) errors
Chapter 5. Error Code to FRU Index
129