Specifications

Table 6. Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
21F2 0004 SCSI read/write optical - send
diagnostic failed - DevOfl cmd
Before replacing any system
components, refer to the notes in
error code 21A0 0001. Replace the
SCSI device.
2200 0001 PCI Ethernet BNC/RJ-45 or PCI
Ethernet AUI/RJ-45 adapter internal
wrap test failure
Replace the adapter. See
“Determining Location Code” on
page 99 for location code information
related to this error. See “Replacing
the Network Adapter” on page 99 for
adapter information related to this
error.
2200 1001 10/100 Mbps Ethernet PCI adapter
internal wrap test failure
Replace the adapter. See
“Determining Location Code” on
page 99 for location code information
related to this error. See “Replacing
the Network Adapter” on page 99 for
adapter information related to this
error.
2201 0001 PCI Auto LANstreamer token ring
adapter failed to complete hardware
initialization.
Replace the adapter. See
“Determining Location Code” on
page 99 for location code information
related to this error. See “Replacing
the Network Adapter” on page 99 for
adapter information related to this
error.
2201 1001 PCI token ring adapter failed to
complete hardware initialization.
Replace the adapter. See
“Determining Location Code” on
page 99 for location code information
related to this error. See “Replacing
the Network Adapter” on page 99 for
adapter information related to this
error.
25A0 0001 Cache L2 controller failure 1. Replace the processor card.
Location: P1-C1
2. Replace the system board. (See
note 3 on page 37.) Location: P1.
25A1 0001 Cache L2 SRAM failure Replace the processor card.
Location: P1-C1
Chapter 5. Error Code to FRU Index
123