Specifications

Table 6. Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
20EE 0006 No recognized SCSI adapter present This warning occurs when the
selected SMS function cannot locate
any SCSI adapter supported by the
function. If a supported SCSI adapter
is installed:
1. Replace SCSI adapter(s).
2. Replace the system board. (See
note 3 on page 37.) Location: P1
20EE 0007 Keyboard not found 1. Plug in keyboard.
2. Replace the system board. (See
note 3 on page 37.) Location: P1
20EE 0008 No configurable adapters were found
in the system by the remote IPL
menu in the SMS utilities
This warning occurs when the remote
IPL menu in the SMS utilities cannot
locate any LAN adapters that are
supported by the remote IPL function.
If a supported device is installed:
1. Replace the device or adapter.
2. Replace the I/O drawer planar in
the drawer(s) containing the
adapter.
20EE 0009 Unable to communicate with the
service processor
Replace the system board. (See note
3 on page 37.) Location: P1
20EE 000B The system was not able to find an
operating system boot record on the
devices listed in the boot list. This
can be caused by the wrong devices
being in the boot record, a problem
that prevents the system from
communicating with the device that
contains the boot record, or the boot
record being corrupted.
Go to “Boot Problems and Concerns”
on page 96.
114 Service Guide