Specifications
Table 6. Firmware Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
20A8 0001 Client IP address is already in use by
other network device
Change IP address.
20A8 0002 Cannot get gateway IP address Refer to Table 2 on page 85 using
code E174.
20A8 0003 Cannot get server hardware address Refer to Table 2 on page 85 using
code E174.
20A8 0004 Bootp failed Refer to Table 2 on page 85 using
code E175.
20A80005 File transmission (TFTP) failed. Check network connection, try again.
20A8 0006 Boot image too large Contact your next level of support for
assistance.
20D0 000F Self-test failed on device, no error
and/or location code information
available
Refer to “System Location Codes” on
page 24 to see if a location code is
available for the device the error was
reported against.
1. Replace device indicated by the
location code (if available).
2. Go to “MAP 1540: Minimum
Configuration” on page 52
20D0 0010 Self-test failed on device, cannot
locate package
Contact your service support
representative for assistance.
20D0 0011 Firmware RTAS attempt to allocate
memory failed.
Contact your next level of support for
assistance.
20E0 0xxx Security
20E0 0001 Privileged-access password entry
error.
The password has been entered
incorrectly. Retry installing the
password.
20E0 0004 Battery drained or needs replacement 1. Replace battery.
2. Replace the system board. (See
note 3 on page 37.) Location: P1
20E0 0009 Invalid password entered - system
locked
The password has been entered
incorrectly 3 times.
Turn off, then turn on the system unit,
then enter the password correctly.
20EE 0003 IP parameter requires 3 dots ″.″ Enter valid IP parameter.
Example: 000.000.000.000
20EE 0004 Invalid IP parameter Enter valid IP parameter.
Example: 000.000.000.000
20EE 0005 Invalid IP parameter (>255) Enter valid IP parameter.
Example: 255.192.002.000
Chapter 5. Error Code to FRU Index
113