Specifications

Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 840B VPD +5 stuck low Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
1011 840C Memory DIMM misplugged Inspect system memory for proper
installation of memory riser cards and
DIMMs.
1011 840D SPCN configuration mismatch System board, Location: P1
1011 840E SPCN default configuration loaded System board, Location: P1
1011 840F Configuration ID not recognized System board, Location: P1
1011 8413 Invalid processor 1 VPD Processor card, Location: P1-C1
1011 8423 No processor 1 VPD Processor card, Location: P1-C1
1011 9012 Invalid address System board, Location: P1
1011 9013 Invalid address System board, Location: P1
1011 9014 Invalid address mode Update system firmware
1011 9038 Slave node fault System board, Location: P1
1011 9039 Rack node fault System board, Location: P1
1011 9042 EEPROM failure System board, Location: P1
1011 9043 Download failure 1. Check for system firmware
update.
2. Call service support.
1011 9046 QDS packet sequence error 1. Check for system firmware
update.
2. Call service support.
1011 9047 QDS block sequence error 1. Check for system firmware
update.
2. Call service support.
1011 9080 Undefined status code received System board, Location: P1
1011 90F0 Rack dropped from configuration 1. Reset system and reboot
2. System board, Location: P1
1011 9101 SPCN failed to respond to CSP in
time
System board, Location: P1
1011 9102 Permanent address assignment failed System board, Location: P1
1011 9103 Download initialize timeout System board, Location: P1
1011 9104 Download completion timeout System board, Location: P1
1011 9105 Load damaged timeout System board, Location: P1
1011 9109 Download failure System board, Location: P1
1011 9114 Firmware image corrupted System board, Location: P1
110 Service Guide