Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 7631 Missing fan 3 Fan 3, Location: F3
1011 7640 Fan 4 failure
1. Fan 4
Location: F4
2. System board
Location: P1
1011 7641 Missing fan 4 Fan 4, Location: F4
1011 7650 Power supply 1 fan failure
1. Power supply 1
Location: V1
2. System board
Location: P1
1011 7651 Missing power supply 1 fan Power supply 1, Location: V1
1011 7660 Power supply 2 fan failure
1. Power supply 2
Location: V2
2. System board
Location: P1
1011 7661 Missing power supply 2 fan Power supply 2, Location: V2
1011 7670 Power supply 3 fan failure
1. Power supply 3
Location: V3
2. System board
Location: P1
1011 7671 Missing power supply 3 fan Power supply 3, Location: V3
1011 8400 VPD configuration problem Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
1011 8401 VPD access problem Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
1011 8402 VPD access problem Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
1011 8403 VPD level mismatch Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
1011 8404 Processor VPD mismatch 1. Processor card, Location: P1-C1
2. System board, Location: P1
1011 8409 Processor VPD
1. Ensure that the processor card is
the correct type for the system
and is properly installed.
2. Processor card, Location: P1-C1
1011 840A VPD +5 stuck high Ignore all location codes.
Go to MAP 1540: Minimum
Configuration.
Chapter 5. Error Code to FRU Index