Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 1531 Power supply 1
1. Power supply 3
Location: V3
2. If the problem is not resolved,
reinstall the original supply in
location V3. Then replace power
supply 1, location V1, with the
new supply.
3. If the problem is not resolved,
reinstall the original supply in
location V1. Then replace power
supply 2, location V2, with the
new supply.
4. Replace the system board
Location: P1
1011 1532 Power supply 3
1. Power supply
Location: V3
2. System board
Location: P1
1011 1533 Power supply 3
1. Power supply
Location: V3
2. System board
Location: P1
1011 1534 Power supply 3
1. Power supply
Location: V3
2. System board
Location: P1
1011 1536 Power supply 3 missing Power supply, Location: V3
1011 1611 CEC regulator 1 fault Processor unit, Location: P1-C1
1011 1612 CEC regulator 1 non-power fault
1. Processor unit
Location: P1-C1
2. System board
Location: P1
1011 1613 CEC regulator 1 domain fault Processor unit, Location: P1-C1
1011 1621 CEC regulator 2 fault Processor unit, Location: P1-C1
1011 1622 CEC regulator 2 non-power fault
1. Processor unit
Location: P1-C1
2. System board
Location: P1
1011 1623 CEC regulator 2 domain fault Processor unit, Location: P1-C1