Specifications
SPCN Error Codes
Attention: If a power supply or fan is hot-swapped, wait five minutes, then recheck
the AIX error log. If the system has to be shut down to replace a power supply or fan,
reboot the system, wait five minutes after the AIX login prompt appears, then recheck
the AIX error log. If the detailed information for the most recent error with the same
identifier indicates that the original problem has not been fixed by performing the first
action in the action column, continue with the next action in the action column.
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 52 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to ″MAP
410: Repair Checkout″ in
Diagnostic Information for Multiple Bus Systems
.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 5. SPCN Error Codes
Error Code Description Action/ Possible Failing FRU
1011 00AC ac loss or brownout detected Information message
1011 00EF Room emergency power off detected Information message
1011 1510 Power supply 1 ac source failure 1. Check power input to power
supply.
2. Power supply, Location: V1
3. System board, Location: P1
1011 1511 Power supply 1
1. Power supply 1,
Location: V1
2. If the problem is not resolved,
reinstall the original supply in
location V1. Then replace power
supply 2, location V2, with the
new supply.
3. If the problem is not resolved,
reinstall the original supply in
location V2. Then replace power
supply 3 (if present), location V3,
with the new supply.
4. Replace the system board
Location: P1
1011 1512 Power supply 1
1. Power supply,
Location: V1
2. System board
Location: P1
104 Service Guide