Specifications

Operator Panel Error Codes
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 52 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to MAP
410: Repair Checkout in
Diagnostic Information for Multiple Bus Systems
.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 4. Operator Panel Error Codes
Error Code Description Action/ Possible Failing FRU
0000 1111 At power on, failure of power-good
signal from power supply
1. System board
Location: P1
2. Power supply
Location: V1 or V2 or V3
0000 1112 At power off, failure of power-good
signal from power supply
1. System board
Location: P1
2. Power supply
Location: V1 or V2 or V3
0000 1113 While power on, failure of
power-good signal from power supply
1. System board
Location: P1
2. Power supply
Location: V1 or V2 or V3
0000 1114 Operator panel and service processor
have been reset after main power
disturbance.
Information message
0000 2222 Operator panel not communicating
with service processor
1. If system cannot be powered off,
reset the service processor (by
activating the pinhole reset switch
or by disconnecting, then
reconnecting, power).
2. System board, Location: P1
0000 3333 SPCN communications error System board, Location: P1
0000 3334 I2C repeater error System board, Location: P1
0000 BBBB TOD battery malfunction Location: P1-V4
Chapter 5. Error Code to FRU Index