Specifications

Table 2. Firmware Checkpoints (continued)
Checkpoint Description Action/ Possible Failing FRU
E51y (E511 - E5FF)
Where y is not equal
to 0.
Configure remote I/O subsystem
components
The E51y (E511 to E5FF) codes
are reserved for activities relating
to configuration or testing of the I/O
subsystem, or remote I/O
subsystem. A hang at one of these
codes implies that a severe error
occurred during the programming
of I/O subsystem registers or when
interacting with adapters plugged
into the system. The last two digits
in the checkpoint can be used to
help isolate the location of the I/O
activity that caused the problem.
y indicates the PCI bus
occurrence.
If y=_, then the PCI bus is:
Y = PCI bus
1=0
2=1
See “AIX and Physical Location
Code Tables” in Chapter 1, for
location codes.
Using the information above, go to
“MAP 1540: Minimum
Configuration” on page 52.
E600 SSA PCI adapter open firmware
has run successfully.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
“Determining Location Code” on
page 99.
E601 SSA PCI adapter BIST has started
but failed to complete after four
seconds.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
“Determining Location Code” on
page 99.
E602 SSA PCI adapter open firmware
has started.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
“Determining Location Code” on
page 99.
E603 SSA PCI adapter BIST has
completed with an error.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
“Determining Location Code” on
page 99.