18. If a failure occurs in the 7133, the ID display shows an error ID alternating with the
enclosure ID. Table 1 shows these error IDs.
Table 1. Error IDs and Their Related SRNs
Error ID See SRN
BP1
BP16
80241
80242
BP4
BP5
80243
80244
BP8
BP9
80245
80246
BP12
BP13
80247
80248
CODE 80210
COLD 80253
COOL 80254
CTRL 80210
FAN1 80231
FAN2 80232
FAN3 80233
HOT 80251
OPNL 80211
POST-FAIL-XXXX
Where XXXX=
XROM WDOG IROM
IRAM LED! I2C
RTC1 RTC2 TIME
UART FAN XRAM
80210
PSU1 80221
PSU2 80222
SLOT 80260
WARM 80252
Note: If the COLD or HOT error ID remains for four minutes, the internal dc power
switches off (that is, the 7133 enters Standby mode).
If the error ID is COLD, the internal dc power switches on automatically
after the temperature has increased and has remained more than 5°C
above the critical temperature for 15 minutes.
If the error ID is WARM, the error is not reset until the ambient temperature
has fallen at least 2°C below the warning level.