Installation guide

Connecting the Remote-Power-On Control Unit
1. Using the preinstallation planning information, or other relevant information,
determine whether the 7133 is to be connected to one using system or to two.
2. Refer to Figure 11.
3. If the 7133 is to be connected to only one using system, connect two using-system
power-control cables to the MAIN connectors (J3 and J4) 1.
If the 7133 is to be connected to two using systems, connect two using-system
power-control cables to the MAIN connectors (J3 and J4) 1 and two using-system
power-control cables to the AUX connectors (J1 and J2) 2.
4. Connect the other ends of the using-system power-control cables to the using
system (see the using-system Installation and Service Guide, or equivalent).
5. Go to Connecting the 7133 Model T40 to the Power Sourceon page 21.
1
1
2
2
Figure 11. Connecting the Using-System Power-Control Cables to the
Remote-Power-On-Control Unit
20 7133 Model T40 Installation Guide