Network Card User Manual

5. (from step 4)
Observe the Status column on the screen. If the status of any pdisk is Failed, that
pdisk is failing. In the example shown here, pdisk2 is failing.
LINK VERIFICATION 802386
SSA Link Verification for:
nunu:ssa0 00-04 IBM SSA 160 SerialRAID Adapter (
To Set or Reset Identify, move cursor onto selection, then press <Enter>.
Physical Serial# Adapter Port
A1 A2 B1 B2 Status
[TOP]
nunu:pdisk11 AC7AA09A 0 5 Good
nunu:pdisk8 AC7AA2D6 1 4 Good
nunu:pdisk2 AC7AA0BD 2 3 Failed
nunu:pdisk3 AC7AA0B1 3 2 Good
nunu:pdisk7 AC7AA0B5 4 1 Good
nunu:pdisk12 AC7AA052 5 0 Good
nunu:pdisk0 AC7AA0B9 0 5 Good
nunu:pdisk1 AC7AA0B3 1 4 Good
nunu:pdisk10 AC7AA0B4 2 3 Good
[MORE...4]
F3=Cancel F10=Exit
Is one of the pdisks failing?
NO Go to step 6 on page 449.
YES
a. Use the Identify function (as instructed on the screen) to find the failing
disk. See Finding the Physical Location of a Deviceon page 409 if
you need more information about finding the disk drive.
b. Exchange the disk drive for a new one (see Exchanging Disk Drives
on page 319).
c. Go to MAP 2410: SSA Repair Verificationon page 475 to verify the
repair.
448 Users Guide and Maintenance Information