Network Card User Manual

SRN Problem Possible Causes
49950 Description: An array copy disk drive is missing. The array copy is
degraded. If the missing disk drive is restored to the network or
exchanged for a new disk drive, the copy rebuilds. A disk drive might not
be available for one of the following reasons:
v The disk drive has failed.
v The disk drive has been removed from the subsystem.
v An SSA link has failed.
v A power failure has occurred.
Action: Go to MAP 2324: SSA RAIDon page 454.
Possible FRUs:
Device (100%)
(Exchanging Disk Drives
on page 319).
4A100 Description: The adapter cannot initialize a disk drive. The failing disk
drive might, or might not, be configured on this system.
Action: Run diagnostics in System Verification mode to all pdisks.
If the diagnostics fail, exchange the pdisk for a new disk drive.
If the diagnostics do not detect a failing pdisk, use the Link Verification
service aid (see Link Verification Service Aidon page 383) to search for
disk drives that are not configured. Such disk drives are listed as *****.
Note: Other adapters in the SSA loop might also be listed as *****.
Exchange, for new disk drives, all pdisks that are not configured.
Possible FRUs:
Device (100%)
(Exchanging Disk Drives
on page 319).
4BPAA Description: A disk drive at PAA cannot be configured, because its UID
cannot be read.
Action: If the SSA service aids are available:
1. Run the Link Verification service aid (see Link Verification Service
Aidon page 383) to find the failing device. The service aid lists the
device as *****.
2. Exchange the FRU for a new FRU.
If the service aids are not available:
1. Note the value of PAA in this SRN, then go to Finding the Physical
Location of a Deviceon page 409.
2. Exchange the FRU for a new FRU.
Possible FRUs:
Device (100%)
(Exchanging Disk Drives
on page 319).
50000 Description: The SSA adapter failed to respond to the device driver.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
50001 Description: A data parity error has occurred.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(Removing and Replacing
an Advanced SerialRAID
Adapteron page 327).
434 Users Guide and Maintenance Information
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|