ATLAS 800 Series System Manual System Config Menu Descriptions
Alarm Relay Reset
Call Stagger Specifies the amount of delay between placing calls for outgoing BONDING
sessions. The following call stagger values are available:
Alarm Relay Reset
Write security: 3; Read security: 5
Clears the Alarm Relay located on the rear panel of the ATLAS 890. Activating the software Alarm Relay
Reset functions the same as manually pressing the ACO Switch located on the ATLAS 890 front panel.
Alarm Relay State
Write security: 3; Read security: 5
Configures the alarm relay response during an active alarm. The following sections are available:
Energized In an alarm condition, the Normally Open (NO) relay is closed and the
Normally Closed (NC) relay is opened.
De-Energized In an alarm condition, the NO relay is opened and the NC relay is closed.
Alarm Relay Threshold
Write security: 3; Read security: 5
Defines the event log category for the message associated with the alarm. For more details on Event Log
categories refer to System Event Log on page 353.
Ext. Input Threshold (ATLAS 890)
Write security: 3; Read security: 5
Defines the alarm level and text for external switch contacts. If the external switch contact is closed, the
alarm is thrown and the event text is sent to the event log.
Name Read security: 5
Displays the name External Input to identify the entry for the external input
alarm.
Description Write security: 3; Read security: 5
Contains the user-defined text that will be sent to the ATLAS 800 Series event
log when the alarm is triggered.
Submenus Description
No Stagger
There is no delay between the call dialing of a BONDING session.
500 ms
Wait approximately ½ second between the call dialing of a BONDING session.
1 sec
Wait approximately 1 second between the call dialing of a BONDING session.
2 sec
Wait approximately 2 seconds between the call dialing of a BONDING session.