Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 85
ATLAS 800 Series System Manual System Config Menu Descriptions
Admin Port
Admin Port
Write security: 2; Read security: 5
Accepts input for configuring the ADMIN port located on the rear of the unit.
Port Name Defines the name of the ADMIN port. You can leave this field blank.
Port Type Specifies whether you use DIRECT or DIAL mode. DIRECT mode is used when
connecting to a VT100 terminal, and
DIAL mode is used for modem access.
Port Speed Specifies the baud rate of the port. Select either 2400, 9600, 19200, or 38400. If
you are using
DIAL for PORT TYPE, ensure that the PORT SPEED setting matches
the modem baud rate.
Modem Initialization
String Specifies the initialization string for a modem. Refer to your modem
documentation for acceptable initialization strings. The default value will set
most modems to the appropriate configuration for the ATLAS 800 Series.
Initialize Modem Write security: 4; Read security: 5
Sends the modem initialization string to the modem. When you select this
command, the following message displays: Please verify a modem is connected
to the Admin port before continuing. Confirm (y/n). Ensure that a modem is
connected before selecting
Y.
Flow Control This option sets the flow control for the ADMIN port. You may configure the
ADMIN port flow control for NONE or HARDWARE.
Craft Port
Write security: 2; Read security: 5
Accepts input for configuring the CRAFT port located on the front of the unit.
Port Name Defines the name of the CRAFT port. You can leave this field blank.
Port Speed Specifies the baud rate of the port. Select either 2400, 9600, 19200, or 38400 to
match the VT100 terminal (or emulator) settings.