Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 78
ATLAS 800 Series System Manual System Status Menu Descriptions
Craft Port
Craft Port
Write security: 2; Read security: 5
Displays the status of the CRAFT port.
Tx Bytes Displays the number of bytes transmitted from the CRAFT port.
Rx Bytes Displays the number of bytes received by the CRAFT port.
Overrun Errs Displays the number of overrun errors received by the CRAFT port.
Framing Errs Displays the number of framing errors received by the CRAFT port.
Clear Counters Write security: 5; Read security: 5
Clears the
CRAFT port statistics. Press Y to activate this command.
System Alarms (ATLAS 830)
Read security: 5
Contains alarm information about the ATLAS system including power and
temperature alarms. The following status symbols are used:
Power Indicates that one or both of the power supplies are not functional. Both the
primary and auxiliary (installed in slots 7 and 8 of the ATLAS 830) power
supplies are continuously monitored to determine failures. If one of these
supplies fails, a message will be placed in the
EVENT LOG (see System Event Log
on page 353 for more details).
Temperature Indicates that the internal temperature of the power supply has exceeded normal
operating limits. When the operating temperature is exceeded by any power
supply, a warning will be placed in the
EVENT LOG but no other action will be
taken (see System Event Log on page 353 for more details).
Symbol Description
[–]
Normal condition
[*]
Failure condition
[!]
No information available