Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 48
ATLAS 800 Series System Manual Option Module Pinouts
Engineering Guidelines
NxT1 HSSI/V.35 Option Module
The NxT1 HSSI/V/35 Option Module (P/N 1200771L1) uses a single 50 pin SCSI-II interface (or V.35
interface using an optional adapter cable) to combine eight T1s of data (a combination of eight using the
four NxT1 HSSI/V.35 Module T1 ports and other T1 ports installed in the system). See Pinouts 30 and 31.
Pinout 30. NxT1 HSSI/V.35 Module (RJ-48C)
Pin Name Description
1 RxData - Ring (R) Receive data from the network
2 RxData - Tip (T) Receive data from the network
3Unused
4 TxData - Ring (R1) Send data towards the network
5 TxData-Tip (T1) Send data towards the network
6,7,8 Unused
Pinout 31. NxT1 HSSI/V.35 Module (50-pin SCSI-II and V.35 Winchester)
Pin
(+ Side)
Pin
(- Side)
Direction Description
1 26 HSSI SG - Signal Ground
2 27 O HSSI RT - Receive Timing
3 28 O HSSI CA - DCE Available
4 29 O HSSI RD - Receive Data
5 30 O HSSI LC - Loopback Circuit C
6 31 O HSSI ST - Send Timing
7 32 HSSI SG - Signal Ground
8 33 I HSSI TA - DTE Available
9 34 I HSSI TT - Terminal Timing
10 35 I HSSI LA - Loopback Circuit A
11 36 I HSSI SD - Send Data
12 37 I HSSI LB - Loopback Circuit B
13 38 HSSI SG - Signal Ground
39 Ancillary to DCE (Reserved)
14 I V.35 RTS - Request to Send
15 40 I V.35 TT Terminal Timing