Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 359
ATLAS 800 Series System Manual System Events
System Event Log
3. SYSTEM EVENTS
Table 1 through Table 8 provide listings of ATLAS system events, including tables of events for each
category, according to the order they appear in the E
VENT LOG setup screen.
Table 1. System Controller Events
Console Log String Category Event
AC Power Supply has Recovered CRITICAL AC power supply is functioning normal again
AC Power Supply has Failed CRITICAL AC power supply is not operating properly
AC Power Supply has Exceeded
Temperature Limit
CRITICAL
Internal system temperature has exceeded
safe operating limit
AC Power Supply is Under Temperature
Limit
CRITICAL
Internal temperature has cooled to safe
operating limit
DC Power Supply has Recovered CRITICAL
DC power supply is functioning normally
again
DC Power Supply has Failed CRITICAL DC power supply is not operating properly
DC Power Supply has Exceeded
Temperature Limit
CRITICAL
Internal system temperature has exceeded
safe operating limit
DC Power Supply is Under Temperature
Limit
CRITICAL
Internal temperature has cooled to safe
operating limit
Firmware invalid CRITICAL Corrupted firmware
Firmware update failed CRITICAL Flash download failed
System Configuration Uploaded CRITICAL
ATLAS configuration file loaded into the
system and activated
Module Not Responding WARNING Module removed or not responding
ACO Switch pressed MINOR ACO switch pressed
Login Failure MINOR
Console login failure
1
1 Three consecutive logins were attempted and failed.
Timing source changed to Internal MINOR Neither the primary nor the backup are valid
Timing source changed to Backup MINOR
The primary source is invalid; backup
source valid and selected.
Timing source changed to Primary MINOR The timing source changed to primary
Not responding to programming MINOR Unable to program module
Cold NORMAL
System cold start
2
2 Generated five seconds after the completion of system initialization.
Firmware update completed INFO Flash download successful
Module Found INFO Module found
SNMP Authentication Failure INFO
SNMP authentication failure
3
3 Generated if the ATLAS receives an SNMP request from an SNMP manager defined in the ATLAS SNMP communities
list but with a community name that does not match the community name defined in the SNMP communities list.