Configuring the ATLAS 890 Alarm Monitor
1. Go to the SYSTEM CONFIG menu and press the right arrow key to access the right-pane menus. Then,
select the E
VENT LOGGING menu and press <Enter>. Once in the EVENT LOGGING menu, press the
right arrow key to access the right-pane menus.
2. From the E
VENT LOGGING menu, select the EXTERNAL INPUT menu and set it to the same value as the
A
LARM RELAY THRESHOLD. Any event on the ALARM MONITOR will now be logged in the EVENT
L
OG and set the ALARM RELAY.
Follow-up Procedures
Once this procedure is complete, return to the procedure which referred you to this DLP and continue with
the tasks indicated there.
Complete the following steps only if you wish to monitor for external alarms.