DLP-7 Updating ATLAS Firmware using XMODEM
Introduction
The ATLAS supports firmware updates via the ETHERNET port using either TFTP from a network server or
the A
DMIN or CRAFT interfaces using XMODEM. This procedure outlines the steps for a successful
firmware upgrade using the A
DMIN or CRAFT interfaces and XMODEM software.
Tools and Materials Required
• VT100 terminal or PC with VT100 terminal emulation software
• XMODEM software
XMODEM Instructions for Updating Firmware
1. Connect to the ATLAS using the DB-9 ADMIN or CRAFT interface, or the RJ-45 ADMIN port.
If you are not already connected to the unit’s A
DMIN or CRAFT interface (either with a
VT100 compatible terminal or with a PC running VT100 emulation software), follow the procedure in
DLP-1, Connecting the Terminal or PC to the ADMIN or CRAFT Port. Connecting to the
ADMIN or
CRAFT interface limits the upgrade procedure to XMODEM Only.
2. Login to the unit using the read-write password (see DLP-5, User Access and Password Security
Levels, on page 327 for details).
3. Go to the S
YSTEM UTILITY menu and select the UPDATE FIRMWARE menu; press <Enter>.
4. Select the M
ODULE SLOT menu and press <Enter>. Select the appropriate module slot to update.
Select S
LOT 0 to update the System Controller.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules,
wear an antistatic discharge wrist strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or storing. When working on
modules, always place them on an approved antistatic mat that is electrically grounded.
Selecting ALL MODULES OF A TYPE and SYS CTRL will force a controller reboot during the
update process.