Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 329
DLP-6 Updating ATLAS Firmware using TFTP
Introduction
The ATLAS 800 Series supports firmware updates via the 10/100 BASET Ethernet port using either TFTP
from a network server or the A
DMIN or CRAFT interfaces using XMODEM. This DLP provides the steps to
follow for a successful firmware upgrade using the 10/100 B
ASET Ethernet port and a TFTP Server.
Tools and Materials Required
A PC with a Telnet client software
A TFTP Server accessible on the local network (A TFTP server is provided with the unit as part of the
ADTRAN Utilities software.)
TFTP Instructions for Updating Firmware
1. Connect to the ATLAS using the 10/100 BASET interface. (If you are not already connected to the
unit’s E
THERNET port using Telnet client software, use the procedure in DLP-4, Verifying
Communications Over an IP LAN, on page 324 to connect to the unit.)
2. Login to the unit using the read-write password (see DLP-5, User Access and Password Security
Levels, on page 327 for details).
3. Go to the S
YSTEM UTILITY menu and select the UPDATE FIRMWARE menu; press <Enter>.
4. Select the M
ODULE SLOT menu and press <Enter>. Select the appropriate module slot to update.
Select S
LOT 0 to update the System Controller.
5. Go to the T
RANSFER METHOD menu and select TFTP.
6. Enter the IP address of the network TFTP server into the TFTP S
ERVER IP ADDRESS field.
7. Enter the full path name and filename of the update file into the TFTP S
ERVER FILENAME field.
To prevent electrical shock, do not install equipment in a wet location or during a
lightning storm.
Electronic modules can be damaged by static electrical discharge. Before handling modules,
wear an antistatic discharge wrist strap to prevent damage to electronic components. Place
modules in antistatic packing material when transporting or storing. When working on
modules, always place them on an approved antistatic mat that is electrically grounded.