Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 311
ATLAS 800 Series System Manual Dial Plan
Ckt Backup: User Term - Ifce Config
Backup Criteria Criteria for automatic backup. Note that this setting affects the available options
for
RESTORE CRITERIA.
Restore Criteria This only applies to originating endpoints. These are criteria for automatically
coming out of backup. Note that
NETWORK SUCCESS (network is out of alarm) is
only available when a backup criterion is not
NET/DATA FAIL. Select MANUAL
O
NLY for manual activator.
Startup Delay The amount of time to wait after creating or changing the endpoint before
allowing backup.
Backup Delay The amount of time to delay after detecting an alarm before going into backup.
This only applies to originating endpoints. If the circuit comes out of alarm
before this time has expired, the endpoint will not go into backup.
Restore Delay The amount of time to delay after clearing an alarm before coming out of
backup. This only applies to originating endpoints. If the circuit goes into alarm
before this time has expired, the endpoint will remain in backup.
Max Num Redials The backup endpoint will attempt this many retries before giving up and
declaring a backup failure. This only applies to originating endpoints.
Redial Timer The amount of time delayed between a failed backup call and the redial. This
only applies to originating endpoints.
Submenus Description
Net/Data Fail
DBU is initiated when either the network fails (possible causes include Red,
Yellow, Blue, or LOS alarms) or when the Nx56/64 module detects a loss of
data transitions on the V.35 interface. If Net/Data Fail is selected, the V.35 Nx
INBAND option must be ON. The remote TSU INBAND option must also be
enabled.
When BACKUP CRITERIA is configured for NET/DATA FAIL, the RESTORE CRITERIA
must be MANUAL ONLY.
Net Fail
DBU is initiated when there is a network failure. Possible
causes include LOS, RED, Yellow, or Blue alarms.
Manual The ATLAS will never initiate DBU until it is manually set to
do so.