Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 302
ATLAS 800 Series System Manual Dial Plan
Octal BRI/U: User Term - Ifce Config
Source ID Simplifies the creation of a dial plan in applications where the criterion for
switching calls to a certain endpoint is a function of which endpoint originated
the call.
•
DEFAULT VALUE = 0. Zero is the default ID for all endpoints and all accept
numbers. With default values, all calls are routed based only on the dialed
number.
• Multiple endpoints can have the same
SOURCE ID.
• When creating the
CALL ACCEPT list, specify a SOURCE ID(s) as well as a
dialed number or range of dialed numbers to accept.
For example, an application requires that all calls that originate from Port 1 of
the ATLAS 800 Series in Slot 1 be switched to Port 2 of that same module.
Assign a unique
SOURCE ID (e.g., 7) to Port 1 of the module, and then configure
Port 2 to only accept calls from that unique
SOURCE ID (7).
Swap ANI/DNIS Swaps the ANI and DNIS numbers received from the network. ANI (Automatic
Number Identification) is the billing number of the calling party, and DNIS
(Dialed Number Identification Service) is the called party number.
Octal BRI/U: User Term - Ifce Config
Write security: 3; Read security: 5
This menu allows the user to define option parameters for ports which emulate a BRI connection. Specifies
the configuration parameters for the endpoint.
Switch Type Defines the type of BRI switch the ATLAS 800 Series emulates. If connected to
another ATLAS 800 Series, both need to be set to the same switch type. The
following options are available:
LUCENT 5E, NORTHERN DMS 100, and
NATIONAL ISDN.
SPID List The port, acting as the network, must use a Service Profile Identifier (SPID) and
phone number(s) in order to satisfy the ISDN connection protocol expected by
the user’s terminal adapter (TA).
Submenu Descriptions
Phone Number
The phone number(s) assigned to this BRI phone line.
SPID Number
Defines the SPID number(s) used for this BRI line. Although the value of the
SPID is not significant, a SPID must be entered for each phone number. For
convenience, the SPID can be set to be identical to the phone number.
The ATLAS 800 Series does not support autoSPID detection software which some
terminal adapters offer.
Calls
For user termination, the number of calls which can be received or sent on this
number/SPID is fixed at 2.