Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 300
ATLAS 800 Series System Manual Dial Plan
Octal BRI/U: Network Term - Ifce Config
Source ID Simplifies the creation of a dial plan in applications where the criterion for
switching calls to a certain endpoint is a function of which endpoint originated
the call.
DEFAULT VALUE = 0. Zero is the default ID for all endpoints and all accept
numbers. With default values, all calls are routed based only on the dialed
number.
Multiple endpoints can have the same
SOURCE ID.
When creating the
CALL ACCEPT list, specify a SOURCE ID(s) as well as a
dialed number or range of dialed numbers to accept.
For example, an application requires that all calls that originate from Port 1 of
the ATLAS 800 Series in Slot 1 be switched to Port 2 of that same module.
Assign a unique
SOURCE ID (e.g., 7) to Port 1 of the module, and then configure
Port 2 to only accept calls from that unique
SOURCE ID (7).
Min DS0’s Set this to 1 for typical single-call connections. Setting this greater than 1 will
restrict connections to endpoints supporting aggregation (e.g., BONDING) of
the specified number of DS0s.
Max DS0’s Set this to 1 for typical single-call connections. Setting this greater than 1 will
accommodate connections to endpoints supporting aggregation (e.g.,
BONDING) of up to the specified number of DS0s. This also sets the number of
DS0s presented in the negotiation of outgoing aggregate calls.
Octal BRI/U: Network Term - Ifce Config
Write security: 3; Read security: 5
This menu allows the user to define option parameters for ports which terminate a BRI connection from the
network. Specifies the configuration parameters for the endpoint.
Switch Type Defines the type of BRI switch to which the port is connected. If connected to
another ATLAS 800 Series, both need to be set to the same switch type. The
following options are available:
LUCENT 5E, NORTHERN DMS 100, and
NATIONAL ISDN.