Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 285
ATLAS 800 Series System Manual Dial Plan
T3 and T3 D&I: Network Term - Ifce Config (NFAS)
Network Specific Facility
Voice and Data Enables the sending of appropriate information to the PSTN. The default for this
option is
NORMAL, and in this case no Network Specific Facility Information
Element is sent. Unless one of the services listed below is subscribed to, the
selection should remain set to
NORMAL.
The list below indicates services that may be subscribed to from the PSTN.
These services require that specific information (such as a Network Specific
Facility Information Element) be sent to the network during call setup.
• AT&T Accunet
• AT&T Dial-It 900/Multiquest
• AT&T International-800
• AT&T Long Distance
• AT&T Megacom
• AT&T Megacom 800
• AT&T SDN
• National ISDN INWATS
• Nortel Foreign Exchange
• Nortel InWats
• Nortel OutWats
• Nortel Private Network
• Nortel Tie Trunk
Called Digits
Transferred Some PRI switches may be provisioned to send only a portion of the called
number (like DID). This menu item allows the ATLAS 800 Series to know how
many digits to expect (choose from
NONE, THREE, FOUR, SEVEN, and ALL). The
default is
ALL and would almost always be correct. If less than ALL digits are
sent, then the
PREFIX is defined as follows:
PREFIX displays only if CALLED DIGITS TRANSFERRED is not set to ALL. Enter the
prefix for the digits received. For example, if the number of digits is four and
the number called is 963-8615, the telco’s PRI switch sends only 8615 and the
prefix is set to 963. This entire number is then used to determine which
ATLAS 800 Series user port endpoint should receive the call.
Outgoing Caller ID Defines the number to use to provide Caller ID to the network for outgoing calls
sent through this endpoint. Choose from
SEND AS PROVIDED, SUBSTITUTE IF NOT
PRESENT, or SUBSTITUTE ALWAYS.
The Caller ID number must be specific (i.e., no wildcards).