Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 255
ATLAS 800 Series System Manual Dedicated Maps
Create/Edit Maps
Activate Time Sets the time when the map becomes active if you have selected AUTO in the
ACTIVATE MAP field. Enter this time in hh:mm:ss 24-hour format.
Enbl Day Specifies which days of the week the map is active.
Submenu Description
From Slt
Specifies the slot to use for the FROM connection. When you select this option, a
list of all of the slots and the modules installed in the slots displays. Select the
appropriate slot and press <Enter>.
Port
Specifies the port to use for the From connection. when you select this option, a
list of ports and module types appears. Select the appropriate port and module
type, and press <Enter>.
To Slot/Service
Specifies the slot to use for the second end of a connection. Select this option,
and a list of all of the slots and the modules installed in the slots displays. Pick
the appropriate slot and press <Enter>. A
PKTENDPT or PKTVOICE endpoint may
also be selected as the service for the connection.
Port
Specifies the port to use for the second end of a connection. When you select
this option, a list of ports and module types appears. Select the appropriate port
and module type, and press <Enter>. If a
PKTENDPT or PKTVOICE endpoint is
selected for the
TO SLOT/SERVICE field, the available packet endpoints or packet
voice endpoints will display in the drop down menu after pressing <Enter>.
From Config
Specifies the configuration for the FROM connection. The selections displayed in
this field are based on the type of module selected in the
FROM SLT option. For
detailed information on submenus for a particular module type, please refer to
the
DEDICATED MAPS menu discussion for the appropriate network, option, or
resource module.
To Config
Specifies the configuration for the TO connection. The selections displayed in
this field are based on the type of module selected in the
TO SLT option. For
detailed information on submenus for a particular module type, please refer to
the
DEDICATED MAPS menu discussion for the appropriate network, option, or
resource module.
SIG
Specifies whether the ATLAS 800 Series uses active RBS on the connection.
Selecting
ON allows the ATLAS 800 Series to preserve signaling bits between
the two endpoints of the connection. Selecting
OFF ignores the signaling bits of
the connection. This selection is automatically set to
OFF when RBS does not
apply. For example, a T1-to-Nx connection is set to
OFF.