Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 237
ATLAS 800 Series System Manual Packet Manager
Frame Relay IQ
Port UA Time
Time, in seconds, the port is unavailable due to physical or
Frame Relay outage.
Sig Down TimeTime, in seconds, the signaling state has been down.
Signal Error The number of PVC signaling frames received with protocol
violations.
Signal T/O The number of PVC signal time-outs. Either T391 seconds
elapsed without receiving a response to a poll or T392 seconds
elapsed without receiving a poll.
Sig State Chg The number of state changes for the PVC signaling protocol.
This number includes transitions from down state to up state
and vice-versa.
Rx Full Stat The number of PVC-signaling, full-status frames received.
Tx Full Stat The number of PVC-signaling, full-status frames transmitted.
Rx LI only The number of PVC-signaling, link integrity only frames
received.
Tx LI only The number of PVC-signaling, link integrity only frames
transmitted.
Async Status The number of single PVC status frames received.
Discard Frame The number of frames discarded by the IQ unit.
Aborts The number of frames received without proper flag
termination.
CRC Error The number of frames received with CRC errors.
Octet Align The number of frames received with a bit count not divisible by
eight.
Length Error The number of frames received that are less than 5 bytes or
greater than 4500 bytes.
EA Violation The number of frames received with errors in the EA field of
the Frame Relay header.
Inactive DLCI The number of frames received while the PVC is in the inactive
state.
Invalid DLCI The number of frames received with a DLCI value less than 16
or greater than 1007, not including PVC signaling frames.
View IQ Statistics
Submenus
Description (Continued)