Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 226
ATLAS 800 Series System Manual Packet Manager
Packet Endpnts
Config - Frame
Relay
(continued)
For most applications, leave the following configuration parameters in the default state. Use
caution when changing these parameters: User Poll timer, User Polls Per Status, User Bad
Event Threshold, and User Event Window Size.
User Poll Timer (T391)
Sets the polling interval to the network in seconds.
User Polls Per Status (N391)
Controls how many link integrity polls occur between full status
polls.
User Bad Event Threshold (N392)
Sets the number of bad polling events that will cause the link to be
declared down in N393 polls.
User Event Window Size (N393)
Defines the number of poll events in each monitored window.
To prevent erratic behavior, ensure that this timer (T392) is greater than the T391 on the
user side of the UNI.
If the number of bad polls reaches N392 in any N393 period, the link will be declared down.
When N393 good polls are received, the link will be declared active again.
Net Poll Response Timeout (T392)
Determines how long this packet endpoint will wait without
receiving a poll before declaring the poll bad.
Net Polls Per Status (N391)
Sets the number of link integrity polls before a full status is
transmitted.
Net Bad Events Threshold (N392)
Sets the number of bad polling events that will cause the link to be
declared down in N393 polls.
Net Event Window Size (N393)
Defines the number of poll events in each monitored window.
Config
Submenus
Description (Continued)