Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 213
ATLAS 800 Series System Manual Async-232 Option Module
Configuration
Configuration
Write security: 5; Read security: 5
All of the following configurable parameters apply to the individual Async-232 ports.
Prt Read security: 5
Displays the port number.
Port Name Write security: 3; Read security: 5
Accepts any alpha-numeric name up to 15 characters long, to uniquely identify
each port on the Async-232 Option Module.
Bit Rate Write security: 3; Read security: 5
Configures the fixed DTE port bit rate. Changing this field hangs up an active
call and requires confirmation. Options include the following:
300, 1200, 2400,
4800, 9600, 19.2K, 38.4K, 57.6K,
and 115.2K.
Flow Ctr Write security: 3; Read security: 5
Configures the flow control for the Async-232 port. Options are:
Fmt Write security: 5; Read security: 5
Configures the asynchronous character format options for the Async-232 port.
Call Dir Write security: 3; Read security: 5
Configures the Async-232 port to answer incoming calls and/or originate
outgoing calls. The following options are available:
IN ONLY, OUT ONLY, and IN
& O
UT.
Submenus Description
Hardware
Hardware flow control monitors RTS from the DTE and controls CTS to
indicate flow control status. Hardware flow control should be used in all cases
except when it is not supported by the attached DTE equipment.
Software
Software flow control uses XON and XOFF characters in the data stream to
control flow.
None
No flow control selected for this port.
Submenus Description
Data Bits
Number of data bits per character.
Parity
Parity method used for transmit and receive characters.
Stop Bits
Number of stop bits per character.