Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 204
ATLAS 800 Series System Manual Modem-24 Resource Module
Status
System resource usage for analog call resources can be viewed under the SYSTEM STATUS
menu of the ATLAS. This menu provides detailed resource availability information for each
resource type, including hourly average available, minimum available, and number of times
there were no available resources of a particular type.
Menu Options Description
Resource (Rscr)
Indicates the resource number of the analog call resource. On the Modem-24
Option Module, analog resources are numbered 1-24.
Status
Indicates the current status of the particular analog call resource and displays
new activity as it occurs. The possible status display values are listed below.
n/a Card is not able to determine the status of the analog call
resource.
Available Indicates this resource is available for use as an analog call.
In Use Indicates this resource is currently being used in an analog call.
Testing Indicates this resource is in a test mode and may be unavailable
for use.
Disabled Indicates this resource has been disabled for use as an analog
call resource. This may be done automatically by the system if
a given analog resource does not initialize properly.
Modulation
Displays the modulation scheme being used by the analog resource for a
currently active call. If the analog resource is not in use, this field will display
N/A.
Rx Bit Rate
Displays the receive bit rate of the analog resource for a currently active call. If
the analog resource is not in use, this field will display
N/A.
Tx Bit Rate
Displays the transmit bit rate of the analog resource for a currently active call. If
the analog resource is not in use, this field will display
N/A.
Error Correction
Displays the error correction mode being used by the analog resource for a
currently active call. If the analog resource is not in use, this field will display
N/A.