Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 200
ATLAS 800 Series System Manual Modem-16 Resource Module
Configuration
Configuration
Write security: 5; Read security: 5
Displays the configuration submenus available for both analog and digital resources available on the
option module.
Analog Rsrc Write security: 5; Read security: 5
Displays the configuration parameters for the available analog resources.
Submenus Description
RSRC
Read security: 5
Indicates the resource number of the analog call resource. On the Modem-16
Option Module, analog resources are numbered 1-16 and digital ISDN
resources are numbered 17-32.
Status
Read security: 5
Indicates the current status of the particular analog call resource and displays
new activity as it occurs. The possible status display values are listed below:
n/a Card is not able to determine the status of the analog call
resource.
Available Indicates this resource is available for use as an analog call.
In Use Indicates this resource is currently being used in an analog call.
Testing Indicates this resource is in a test mode and may be unavailable
for use.
Disabled Indicates this resource has been disabled for use as an analog call
resource. This may be done automatically by the system if a
given analog resource does not initialize properly.