Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 193
ATLAS 800 Series System Manual Modem-16 Resource Module
Status
Submenus Description
Resource (Rscr)
Indicates the resource number of the analog call resource. On the Modem-16
Option Module, analog resources are numbered 1-16 and digital ISDN
resources are numbered 17-32.
Status
Indicates the current status of the particular analog call resource and displays
new activity as it occurs. The possible status display values are listed below.
n/a Card is not able to determine the status of the analog call
resource.
Available Indicates this resource is available for use as an analog call.
In Use Indicates this resource is currently being used in an analog call.
Testing Indicates this resource is in a test mode and may be unavailable
for use.
Disabled Indicates this resource has been disabled for use as an analog call
resource. This may be done automatically by the system if a
given analog resource does not initialize properly.
Modulation
Displays the modulation scheme being used by the analog resource for a
currently active call. If the analog resource is not in use, this field will display
N/A.
Rx Bit Rate
Displays the receive bit rate of the analog resource for a currently active call. If
the analog resource is not in use, this field will display
N/A.
Tx Bit Rate
Displays the transmit bit rate of the analog resource for a currently active call. If
the analog resource is not in use, this field will display
N/A.
Error Correction
Displays the error correction mode being used by the analog resource for a
currently active call. If the analog resource is not in use, this field will display
N/A.
Data Compression
Displays the data compression mode being used by the analog resource for a
currently active call. If the analog resource is not in use, this field will display
N/A.
Last Disconnect
Reason
Displays the reason for the previous disconnect which occurred on this analog
resource. If no disconnect has occurred on this analog resource, this field will
display
N/A.
Line Parameters
Displays technical details about the analog resource for the currently active call.
This information may be used when troubleshooting modem connection
problems with the Modem-16 Option Module. See Table 6 on page 194for a
complete listing.