Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 183
ATLAS 800 Series System Manual VCOM Option Module
Config
Config
Write security: 4; Read security: 5
Provides diagnostic tools for suspected problems; under normal operation, users do not configure the
packet voice devices.
Configure VCOM
Devices Write security: 4; Read security: 5
Contains configuration parameters for individual VCOM devices.
Submenu Description
Device
Read security: 5 - Indicates the resource number of the packet voice device
listed. On the ATLAS 800 Series, packet voice devices are numbered 1-32
State
Write security: 4; Read security: 5 - Controls the configuration state of the
individual packet voice device. The ATLAS 800 Series determines the initial
configuration state of each device. ATLAS uses this configuration information
to determine which packet voice devices are functional and may be used, which
are defective and should not be used, or which are not present on the module
and should not be used. Users who suspect an individual packet voice device of
improper operation can manually disable that device to prevent ATLAS from
attempting to use it. The possible states are defined as follows:
Deferred Devices which fail built-in testing are automatically marked as
DEFERRED, indicating that the ATLAS 800 Series declines to
use the device.
Available The device is properly functioning and can be used when
required. The ATLAS 800 Series automatically marks devices
that pass built-in testing as
AVAILABLE.
Disabled Marking a device as DISABLED prevents the ATLAS 800 Series
from attempting to use it. You can mark a device currently in
use as disabled without disturbing the connection, but the
device will not be eligible for use in future calls until you
re-mark it as
AVAILABLE. This is helpful if you suspect that a
particular device is malfunctioning and do not want any calls
routed to it.