Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 166
ATLAS 800 Series System Manual Dual Video Option Module
DTE Interface
511 Result Write security: 5; Read security: 5
Displays the results of the 511 test. This option is read-only. Clear these results
by pressing <Enter > when
CLR is selected.
CLR Write security: 4; Read security: 4
Clears error counters on test pattern results menu.
Inject Write security: 4; Read security: 4
Injects errors into transmitted test pattern.
DTE Interface
Write security: 5; Read security: 5
Configures the DTE port of the Video Module for the appropriate interface type. Select the parameters
matching the interface cable being used.
Prt Displays the port number.
DTE Interface Mode Write security: 3; Read security: 5
Configures the DTE port interface type. The following options are available:
Current DTE Type Write security: 5; Read security: 3
Displays the current configuration of the Video Module DTE Interface.
Results Description
None
Pattern is not synchronized.
LOS
At one point the pattern was synchronized, but is currently not synchronized.
Sync
Pattern is synchronized.
ES
Number of seconds with at least one bit error.
Options Description
Auto
The ATLAS 800 Series will automatically detect the interface type. The cable
must be connected before the interface can be determined.
EIA-530
Configures the interface for EIA-530 use.
V.35
Configures the interface for V.35 use.
RS-449
Configures the interface for RS-449 use.
Loopback
Configures the interface to emulate a connected loopback cable.