Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 163
ATLAS 800 Series System Manual Dual Video Option Module
Data Rate
Data Rate
Write security: 5; Read security: 5
Displays data rate at which each port is currently operating.
Port Indicates port number.
Rate Displays the data rate at which each Video Module DTE port is currently
operating. A port’s data rate is determined by the number of B channels
assigned to it and the rate per channel associated with the active call.
PLL/FIFO
Write security: 5; Read security: 5
Displays the Phase Lock Loop (PLL) and FIFO status.
Port Indicates the operating port.
PLL/FIFO Displays the PLL and FIFO status.
Configuration
Write security: 5; Read security: 5
Describes the configurable parameters which apply to the individual Video Module DTE ports.
Prt Displays the port number.
Name Write security: 3; Read security: 5
Accepts any alpha-numeric name up to 15 characters long, to uniquely identify
each DTE port on the Video Module.
Clk +/- Write security: 3; Read security: 5
Controls the clock used by the ATLAS 800 Series to accept the transmit (TX)
data from the DTE. This is usually set to
NORMAL. If the interface cable is long,
causing a phase shift in the data, the clock can be set to
INVERTED. This switches
the phase of the clock, which compensates for a long cable.
Options Description
Lock
PLL is locked (This is required to transfer data.)
RXE
Receive data FIFO empty.
RXF
Receive data FIFO full.
TXE
Transmit data FIFO empty.
TXF
Transmit data FIFO full.