Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 161
ATLAS 800 Series System Manual Dual Video Option Module
Info
DUAL VIDEO OPTION MODULE
The ATLAS 830 system controller automatically detects the presence of the Dual Video Option Module
(P/N 4200773Lx) when it is installed in the system. To see the menus for this module via the terminal
menu, use the arrow keys to scroll to the
MODULES menu and press <Enter> to access the module choices.
The following menu tree shows the hierarchy of the menus discussed in this section.
Info
Write security: 5; Read security: 5
Provides information about the module part number, serial number, and board revision.
Part Number Displays the part number of the module. (Read-only.)
Serial Number Displays the serial number of the module. (Read-only.)
Board Revision Displays the board revision of the installed module. (Read-only.)
Alarm Status
Write security: 5; Read security: 5
Displays the current alarm status of the DTE interface.
Prt Indicates the port number.
Info Alarm Status DTE Status Data Rate
Part Number Prt Prt Port
Serial Number Alarms DTE Status Rate
Board Revision
PLL/FIFO Configuration Test DTE Interface
Port Prt Prt Prt
PLL/FIFO Name Loopback DTE Interface Mode
Clk +/- Loopback Status Current DTE Type
Data 511
CTS 511 Result
DCD CLR
DSR Inject
DTR
0 Inh