Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 153
ATLAS 800 Series System Manual T3 D&I Option Module
DS3 Performance 15Min
LOSS_L (Loss of Signal Second - Line) Count of seconds of LOS condition.
CV_P (Code Violation - Path) For the M13 applications, an accumulation of P-bit
parity errors. For the C-bit parity application, an accumulation of CP-bit parity
errors.
ES_P (Errored Second - Path) An accumulation of seconds during which any one of
the following conditions exist: parity errors, severely errored frame, or AIS
signal received.
SAS_P (SEF/AIS Second) An accumulation of seconds during which severely errored
frame or AIS signal is received.
SES_P (Severely Errored Seconds - Path) An accumulation of seconds during which
parity errors, severely errored frames, or AIS signal is received.
UAS_P (Unavailable Seconds - Path) An accumulation of one-second intervals during
which the DS3 path is unavailable; i.e., 10 contiguous Sysop.
DS3 Performance 15Min
Write security: 3; Read security: 5
Stores the performance data for the previous 15-minute window. Refer to DS3 Performance Current on
page 145 for a detailed description of these fields.
DS3 Performance 24Hr
Write security: 3; Read security: 5
Stores the performance data for the previous 24-hour window. Refer to DS3 Performance Current on
page 145 for a detailed description of these fields.
DS3 Configuration
Write security: 3; Read security: 5
Includes all of the configurable parameters pertaining to the T3 interface.
Prt Read security: 5
Displays the port number
Port Name Enter any text up to 15 characters to uniquely identify the T3 port on the DS3
Option Module.
Frame Configures the framing format for the T3 circuit. Selections are M13 or C-BIT.