Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 147
ATLAS 800 Series System Manual T3 Option Module
DS1 Performance 15Min
LOFC Loss of Frame Count is a count of seconds in which a valid framing pattern
could not be obtained.
CSS Controlled Slip Second.
UAS Unavailable Second
PCV Path Code Violation.
DS1 Performance 15Min
Write security: 3; Read security: 5
Stores the performance data for the previous 15-minute window. Refer to DS1 Performance Current on page
141 for a detailed description of these fields.
DS1 Performance 24Hr
Write security: 3; Read security: 5
Stores the performance data for the previous 24-hour window. Refer to DS1 Performance Current on page
141 for a detailed description of these fields.
DS1 Configuration
Write security: 3; Read security: 5
All of the following configurable parameters apply to whether the port is connected to a Primary Rate
ISDN circuit or a channelized T1 circuit.
Prt Read security: 5
Displays the T1 number.
Port Name Write security: 3; Read security: 5
Accepts any alpha-numeric name up to 15 characters long, to uniquely identify
each T1 in the T3 circuit
Frame Write security: 2; Read security: 5
This field must be set to match the frame format of the circuit to which it is
connected, available from the network supplier. Choose either
D4 or ESF.
Tx Yel Write security: 3; Read security: 5
Controls the transmission of yellow alarms. Choose either
ON or OFF.
Tx Prm Write security: 3; Read security: 5
Controls the sending of performance report messaging (PRM) data on the
facility data link (FDL). The PRM data continues to be collected even if
XMIT
PRM
is turned off (possible only with ESF format). Choose either ON or OFF.