DS3 Performance 15Min
SES_L (Severely Errored Seconds - Line) Count of seconds containing excessive zeros,
LOS, or BPVs, not due to line code substitutions above a predetermined
threshold.
LOSS_L (Loss of Signal Second - Line) Count of seconds of LOS condition.
CV_P (Code Violation - Path) For the M13 applications, an accumulation of P-bit
parity errors. For the C-bit parity application, an accumulation of CP-bit parity
errors.
ES_P (Errored Second - Path) An accumulation of seconds during which any one of
the following conditions exist: parity errors, severely errored frame, or AIS
signal received.
SAS_P (SEF/AIS Second) An accumulation of seconds during which severely errored
frame or AIS signal is received.
SES_P (Severely Errored Seconds - Path) An accumulation of seconds during which
parity errors, severely errored frames, or AIS signal is received.
UAS_P (Unavailable Seconds - Path) An accumulation of one-second intervals during
which the DS3 path is unavailable; i.e., 10 contiguous SES_Ps.
DS3 Performance 15Min
Write security: 3; Read security: 5
Stores the performance data for the previous 15-minute window. Refer to DS3 Performance Current for a
detailed description of these fields.
DS3 Performance 24Hr
Write security: 3; Read security: 5
Stores the performance data for the previous 24-hour window. Refer to DS3 Performance Current for a
detailed description of these fields.
DS3 Configuration
Write security: 3; Read security: 5
Includes all of the configurable parameters pertaining to the T3 interface.
Prt Read security: 5
Displays the port number
Port Name Enter any text up to 15 characters to uniquely identify the T3 port on the DS3
Option Module.