ATLAS 800 Series System Manual Octal BRI S/T Option Module
Info
OCTAL BRI S/T OPTION MODULE
The ATLAS 800 Series system controller automatically detects the presence of the Octal BRI S/T Option
Module (P/N 1200343L1) when it is installed in the system (listed as
ST-BRI). To see the menus for the
Octal BRI S/T Option Module via the terminal menu, use the arrow keys to scroll to the
MODULES menu
and press <Enter> to access the module choices. The following menu tree shows the hierarchy of the
menus discussed in this section.
Info
Write security: 5; Read security: 5
Provides information about the module part number, serial number and assembly revision.
Part Number Read security: 5
Displays the part number of the module. (Read-only.)
Serial Number Read security: 5
Displays the serial number of the module. (Read-only.)
Board Revision Read security: 5
Displays the board revision of the installed module. (Read-only.)
Alarms
Write security: 5; Read security: 5
Displays the alarm status for the selected Octal BRI S/T Option Module.
Prt Indicates the port number.
Alarms Displays the current alarm status of each Octal BRI S/T interface.
Channel Displays the alarm status of the D-channel alarm. A hyphen (–) indicates no
active channel alarm and D indicates an active D channel alarm.
Info Alarms Channel Usage Configuration Test
Part Number Prt Prt Prt Prt
Serial Number Alarms Cha Port Name Local Loopback
Board Revision Channel Remote Loopback
Alarm Description
L1 Down
A layer one alarm is indicated by an asterisk (*) when the Octal BRI S/T
physical layer is not active. An L1 alarm is present when problems are detected
with the endpoint or a cabling problem.