Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 134
ATLAS 800 Series System Manual Octal BRI U Option Module
Info
OCTAL BRI U OPTION MODULE
The ATLAS 800 Series system controller automatically detects the presence of the Octal BRI Option
Module (P/N 1200186L2) when it is installed in the system (listed as
U-BRI). To see the menus for the
Octal BRI Option Module via the terminal menu, use the arrow keys to scroll to the
MODULES menu and
press <Enter> to access the module choices. The following menu tree shows the hierarchy of the menus
discussed in this section.
Info
Read security: 5
Provides information about the module part number, serial number and assembly revision.
Part Number Displays the part number of the module.
Serial Number Displays the serial number of the module.
Board Revision Displays the board revision of the installed module.
Alarms
Read security: 5
Displays the alarm status for the selected Octal BRI Option Module.
Prt Indicates the port number.
Alarms Displays the current alarm status of each BRI U interface.
Info Alarms Channel Usage Performance Current Configuration Test
Part Number Prt Prt Prt Prt Prt
Serial Number Alarms Cha Reset Port Name Local Loopback
Board Revision NEBE Remote Loopback
FEBE
Alarm Description
L1 Down
A layer one alarm is indicated by an asterisk (*) when the BRI U physical layer
is not active. An L1 alarm is present when problems are detected with the
endpoint or a cabling problem.
Channel
Displays the alarm status of each 2B+D channel. A hyphen (–) indicates no
active channel alarm and D indicates an active D channel alarm.