TS0 Alarms
TS0 Alarms
Read security: 5
Displays per-TS0 alarm status. These alarms usually indicate the failure to receive the protocol that has
been configured for the TS0.
TS0 Status
Read security: 5
The TS0 status indicates usage on a TS0 basis for each port. These options are read-only:
Sig Status (Port 1-4)
Read security: 5
Displays the state of the A/B/C/D signaling bits for the Quad E1/PRA Option Module. Dashes indicate
TS0s where signaling is not being transferred by the ATLAS 800 Series.
Character Description
-
No Alarm TS0
D
D Channel Alarm (ISDN)
F
Frame Alarm (packet)
T
TBOP Alarm (packet)
P
PPP Alarm (packet)
Character Description
•
Idle
–
Inactive
A
Active call on this TS0
D
Active D Channel TS0
M
Maintenance TS0
N
Dedicated (nailed) TS0
O
Off hook detected
R
Ringing detected
S