Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 113
ATLAS 800 Series System Manual Quad E1/PRA Option Module
Alarm Status
Alarm Status
Read security: 5
Displays any active alarms, as follows:
Prt Indicates the port number. The Quad E1/PRA Option Module is a single-port
device.
Alarms Displays the alarm type, as listed below.
Alarm Types Description
LOS
(Loss of Signal) No signal detected on port interface.
LOF
(Loss of Framing) The receiver is unable to synchronize to the Frame
Alignment Signal (FAS) framing pattern of the received signal.
LOMF
(Loss of Multi-frame) The receiver is unable to synchronize to the TS15
multi-frame pattern of the received signal.
CRC4
(Loss of CRC-4 Framing) The receiver is unable to synchronize to the CRC-4
frame pattern of the received signal.
AIS
(Alarm Indication Signal) An upstream failure has been detected and all ones
are being received.
REM
(Remote Frame Alarm) Loss of frame alarm being received from far end.
REMMF
(Remote Multi-Frame Alarm) Loss of multi-frame alarm being received from
far end.