Instruction manual

61200780L1-1C © 2004 ADTRAN, Inc. 104
ATLAS 800 Series System Manual Modules Menu Descriptions
State
State
Read security: 5
Displays whether the ATLAS controller or selected module is online or offline. Even though a module is
physically installed, it must be marked
ONLINE for it to be considered an available resource. This parameter
allows an installed module to be marked
OFFLINE, which may be useful in system troubleshooting. If you
choose
OFFLINE, the module will not be in alarm condition, but will display OFFLINE. While in OFFLINE, the
STATUS LED will flash green. A module will automatically change to the ONLINE state when installed.
Status
Read security: 5
Displays status information on the installed modules as follows:
Online The module is enabled and is responding to the system controller’s status polls.
This is the normal response of the system.
No Response The module is enabled but is not responding to the system controllers status
polls. This response indicates a problem in the system or that the module is not
properly installed.
Empty The system controller has not detected the presence of a module in the system;
nor has a module been manually enabled for this option slot.
Offline The module is installed but has been taken offline by a user. The module is still
responding to controller polls.
Offline/No Response The module is installed but has been taken offline by a user. The module is not
responding to controller polls.
Not Supported The module is not supported by the current system configuration.
Rev
Read security: 5
Displays the hardware revision of the ATLAS and installed modules.