Instruction manual
61200780L1-1C © 2004 ADTRAN, Inc. 103
ATLAS 800 Series System Manual Modules Menu Descriptions
Type
Type
Write security: 3; Read security: 5
Displays the type of module actually installed in the slot or the type of module you plan to install in the
slot. The ATLAS controller automatically detects the type of module installed in each slot, and the
TYPE
field automatically defaults to the installed module type. You can also use this field to preconfigure a unit
before actually installing modules by specifying the module that you want to install in each slot.
To use this option, navigate to the field you want to edit and press <Enter>. For empty slots, a list of all the
available module types displays. Select the one you want and it displays in the
TYPE field. If this field is
already configured with a module, you can only set this field to
EMPTY. To change from one module type to
another, you must set the field to
EMPTY first.
Menu
Read security: 5
Displays additional status and configuration menus for the ATLAS controller or selected module. To
access the submenus for this item, use the arrow keys to scroll to the
MENU column for the module you
want to edit, and press <Enter>. For detailed information on each submenu item for a particular module,
refer to the modules menus discussion for the appropriate option or resource module.
Alarm
Read security: 5
Displays whether there is an alarm condition on the ATLAS controller or selected module. Press <Enter>
to access the
ALARM menu. For detailed information on each submenu item for a particular module, refer to
the following sections for the appropriate option or resource module alarm menu discussions.
Test
Read security: 5
Displays whether the ATLAS controller or selected module is executing a test. Press <Enter> to access the
TEST menu. This option will allow you to setup and initiate tests. You may also access this menu through
the
MENU submenu on this screen. For detailed information on each submenu item for a particular module,
refer to the following sections for the appropriate option or resource module test menu discussions.
Inserting modules into inappropriate slots will result in damage to the ATLAS.
ATLAS 830:
• Auxiliary power supplies are for use in Slots 7 and 8 only.
ATLAS 890:
• System Controller modules are for use in the controller slots SCUA and SCUB only.
• Option Modules are for use in the option module slots 1-16 only.
• Power supplies are for use in the power supply slots 14-17 only.